Attention Problems in Connecting Electronic Control System of "Mianyang Accumulated Gate" Fast Gate


 

快速门电控系统连接时注意问题


Attention Problems in Connecting Electronic Control System of Fast Gate
 

1、当需要对控制系统进行打开、连接、保养或者检查的时候,需要将主电路电源切断。


1. When the control system needs to be opened, connected, maintained or checked, the power supply of the main circuit needs to be cut off.
 

2、主电源切断后,控制系统在5分钟内也有带电,内部电容会有一个延迟存电。


2. After the main power supply is cut off, the control system will also be charged within 5 minutes, and the internal capacitance will have a delayed storage.

 

绵阳厂房快速堆积门安装


3、因存在电流的可能,禁止在此时代触摸电子元件,以免发现意外事故。


3. Because of the possibility of electric current, it is forbidden to touch electronic components in this era in order to avoid accidents.

4、实现接线后,在进行第一次运行的时候,必须对控制箱的接线和电机的接线进行细致的检查。尤其电机等部件是否连接正确,否则可能对变频器造成不可修复的损坏。


4. After wiring, the wiring of control box and motor must be carefully checked during the first operation.Especially if the motor and other components are connected correctly, otherwise it may cause irreparable damage to the frequency converter.
 

5、所有从控制电源至控制系统的电源绝缘必须良好,推荐应用大于230V的检测设备对电源的绝缘层进行检测。


5. All the power supply insulation from the control power supply to the control system must be good. It is recommended that the insulation layer of the power supply be tested by the testing equipment larger than 230V.

 

 

成都快速门控制方式

6、根据EMC指令,电机电缆可以应用带屏蔽层的电缆。屏蔽必须在两端接地相连。该屏蔽层不可有任何电压。


6. According to EMC instructions, motor cables can be used with shielded cables. Shielding must be grounded at both ends. The shielding layer must not have any voltage.

7、快速门由于存在告诉运动而使门帘之间摩擦,在摩擦的过程中可能带有大批静电,如果不及时释放,可能回导致控制单元损坏。以是需要做放静电的相关保护措施。
 

 7. The friction between the curtains is caused by the telling motion of the fast door. There may be a lot of static electricity in the process of friction. If it is not released in time, it may lead to the damage of the control unit. Therefore, it is necessary to take some protective measures for electrostatic discharge.


「绵阳堆积门」快速门电控系统连接时注意问题

Attention Problems in Connecting Electronic Control System of "Mianyang Accumulated Gate" Fast Gate


联系我们CONTACT US
版权所有:成都龙盛门业北京福彩网
电话:18248288962
联系人:艾经理
全国客服:4006080090
网址:http://www.yilongmall.com
查看更多
电话:18248288962(媒体勿扰)    联系人:艾经理
版权所有:成都龙盛门业北京福彩网
百度地图 - 网站地图 -
山西福彩网 无锡体彩网 天津福彩网 无锡体彩网 中国竞彩网 山西福彩网 陕西福彩网 陕西福彩网 陕西福彩网 无锡体彩网